LCP Distal Medial Tibia 3.5mm

Buy Now (WhatsApp)

The LCP Distal Medial Tibia 3.5mm (Low Bend) is an anatomically contoured, side-specific implant designed for the internal fixation of fractures and osteotomies of the distal tibia, particularly those involving the medial malleolus or shaft. Its low-bend profile is optimized for placement on the medial aspect of the distal tibia. Utilizing LCP (Locking Compression Plate) technology, it provides fixed-angle stability to resist axial load and shear forces, crucial for maintaining reduction in the distal articulating segment. The plate is designed for use with 3.5mm screws.


Key Features

  • Low Bend Profile: Optimized anatomical contour for the medial distal tibia.

  • Anatomical Contour: Side-specific shaping (Left/Right) ensures a precise fit on the distal medial tibia.

  • LCP Locking: Provides fixed-angle stability crucial for maintaining reduction and structural integrity.

  • Screw Diameter: Designed for use with 3.5mm screws.

  • Primary Use: Indicated for fractures and osteotomies of the distal tibia, including medial malleolus fractures.

Additional Information

Technical Information

The LCP Distal Medial Tibia 3.5mm (Low Bend) is an anatomically contoured, side-specific implant designed for the internal fixation of fractures and osteotomies of the distal tibia, particularly those involving the medial malleolus or shaft. Its low-bend profile is optimized for placement on the medial aspect of the distal tibia. Utilizing LCP (Locking Compression Plate) technology, it provides fixed-angle stability to resist axial load and shear forces, crucial for maintaining reduction in the distal articulating segment. The plate is designed for use with 3.5mm screws.


Key Features

  • Low Bend Profile: Optimized anatomical contour for the medial distal tibia.

  • Anatomical Contour: Side-specific shaping (Left/Right) ensures a precise fit on the distal medial tibia.

  • LCP Locking: Provides fixed-angle stability crucial for maintaining reduction and structural integrity.

  • Screw Diameter: Designed for use with 3.5mm screws.

  • Primary Use: Indicated for fractures and osteotomies of the distal tibia, including medial malleolus fractures.

Variants & Codes

Right Plate Variants

Hole Stainless Steel Titanium
5 371.005 976.005
7 371.007 976.007
9 371.009 976.009
11 371.011 976.011
13 371.013 976.013

Left Plate Variants

Hole Stainless Steel Titanium
5 369.005 974.005
7 369.007 974.007
9 369.009 974.009
11 369.011 974.011
13 369.013 974.013